Network PA System for tool to massive tasks



Introduction


The XC-9000 system is a completely digital network PA system based on the TCP/IP procedure. By leveraging the TCP/IP method, the system guarantees the efficient and appropriate transmission of all data packets. Not only can it use existing local area network, such as LANs or the Internet, to transmit program signals, yet also it can likewise be deployed on a committed broadcasting network.


The web server is very powerful. Even when gotten in touch with a multitude of terminals, it can all at once handle the very same task efficiently. A single-server system can support approximately 3000 terminals and permits for server cascading. There are no limitations on the simultaneous broadcast channels, accomplishing real full digital broadcasting
.


System Characteristics



Adaptable PA System Style


The PA system design is easy, including solution monitoring software, network microphones, network amplifiers, network audio speakers, and other devices.All equipment is attached through the TCP/IP intranet protocol, allowing for adaptable arrangement and very easy administration of the system, with free control over broadcast material, network tools, and areas through the network.


Ip Paging SystemIp Speaker
Comprehensive Audio Monitoring


The audio monitoring software program consists of built-in features for developing broadcast plans, versatile zoning, and pre-scheduled broadcasts.It supports 24-hour programs, permitting transforming setups during all the time


Versatile Sound Resource Support


The system supports different forms of audio resources for sending notifications like real-time speech and BGM playback. Sound sources can originate from electronic musical apps, CD/DVD gamers, microphones, etc. Furthermore, the system offers varied features of supporting different broadcasting features such as arranged broadcasting, zoned broadcasting, and emergency situation broadcasting.


Smoke Alarm System Integration


The system has an emergency alarm feature and can be integrated into a fire alarm system. When the alarm system main unit gets the disconcerting signals, the cable will certainly send the signal to devices, which activates the XC-9000, sending out signals to audio speakers


Users might pick to preset settings to trigger full-area or zoned alarm systems in emergencies. The alarm voices can be found in numerous forms and could be modified accommodating requirements. For instance, users can change language settings, upload and modify their audio sources according to precise demands, such as intruding alarm systems, smoke alarm or air aid alarm systems, etc





Emergency Alarm System Integration


The system has a smoke alarm feature and can be integrated into a smoke alarm system. When the alarm central device obtains the alarming signals, the cable will transmit the signal to devices, which sets off the XC-9000, sending signals to audio speakers


Customers might select to pre-programmed setups to trigger full-area or zoned alarm systems in emergencies. The alarm system voices come in numerous kinds and could be edited accommodating needs. As an example, individuals can alter language setups, upload and modify their audio resources according to precise demands, such as intruding alarms, fire alarms or air help alarms, etc





App Control for System Operations


The system enables mobile application login and usage, enabling individuals to launch broadcasts and other procedures to accredited terminals via the web server software application, guaranteeing a convenient and structured experience.


Integrated SIP Compatibility


The system not only permits SIP phones to visit, however likewise can be linked to third-party SIP server or IPPBX, which develops a totally integrated and compatible interaction system with seamless assimilation right into existing systems.


Open up SDK


When big project like clever park happens, the system offers an open SDK incorporated into third-party application systems - IP Speaker


System Infrastructure



Main Features


Set up Playback


The system is able to instantly transmit according to the set up jobs as long as individuals upload the audio apply for each period of the day to the server and produce a playback schedule.


Zone Broadcasting


The system can randomly divide a few network devices right into various zones to play defined audio programs or send out announcements to any kind of designated location. The quantity of each tool can be remotely readjusted.


Real-time Broadcasting


The system can catch and relay radio programs or various other exterior audio sources in real-time, and at the exact same time broadcast them in sync.


Fire Alarm Combination


The system can be incorporated with the smoke alarm system for control. When a fire alarm signal is activated, it instantly triggers the emergency situation broadcast function and supports surrounding floor alarm systems. It likewise permits hands-on emergency broadcasting by clicking a single button.


SIP Phone Assimilation


The system can be incorporated with SIP web servers, he has a good point permitting live speech of voice broadcasting by means of SIP phones to send out news anytime and anywhere.


CCTV Assimilation


The digital devices such as IP POE Speakers embraces the global common ONVIF method, which allows their voices to be broadcast by means of VMS systems. The terminals can also be integrated with CCTV systems for synchronized broadcast.


Main Products



Audio Administration Software XC-9000


B/S architecture, supports cross-platform applications.
Covers conventional see this broadcasting system operates, permitting dividing management.
Unified management of terminals within the system, viewing work standing, and set quantity change, and so on.
Sustains structure multi-level web server styles, releasing administration according to user geographical regions.
Provides SDK development plans for second advancement and assimilation with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Communication Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Feedback: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Interaction Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Intercom: Sustained, Integrated Microphone.
Operating Temperature level: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.


Network Ceiling Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Protocols: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Running Temperature: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Surface Mount Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Feedback: 100Hz~ 18KHz.
Operating Temperature level: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.


Network Column Audio Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Regularity Action: 45Hz~ 18KHz.
Operating Temperature level: -10~ 55 ℃.
Dimensions: 296x140x130mm.


Network Audio Bridge GEN-3101A01


Power Supply: POE.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Frequency Feedback: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Dimensions: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Reaction: 60Hz~ 18KHz.
Operating Temperature: -10~ 50 ℃.
Measurements: 440x300x44mm.


Area Mixing Digital Amplifier NBS-2301


Power Supply : A/C 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Reaction :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature level :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Dimensions : 483x430x88mm.


IP Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Procedure: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm outputs.
Operating Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Remedy For College





Flexible Zoning Broadcast:


The totally network terminals can understand check my site flexible zoning options, enabling broadcasting notifications to individual terminals or various zones ( tools).


Institution Bell System:


It gives school bell system at the beginning/ending of the class - SPON Communications. Several circumstances can be developed, including various set up program tasks according to summer/winter timetable


Smoke Alarm Integration


It sustains combination with fire alarm system systems, enabling smoke alarm signals to be integrated into the PA system.


Classroom Sound Amplification


Terminals sustain everyday applications in classroom scenes. They can be connected to projectors or interactive whiteboard for audio boosting.


Ip Paging SystemSpon Communications

Smart Road Lamp/Security Post



Support SIP Method:


Integrated SIP procedure for smooth integration with network interaction systems.


VMS Platforms Integration:


Integrated ONVIF method for assimilation with VMS systems.


Third-Party Integration:


Integrated In HTTP API for combination with 3rd party systems.


Voice Alarm System Setting Off:


Integrated in alarm system input interface for activating voice alarms with electronic cameras.


Service For Resort



Zone Control by Floor:


The system provides complete network setups, separating areas relying upon various floors and control over each area separately.


Fire Alarm System Combination:


The system can be integrated with emergency alarm system, allowing integration of emergency alarm signals into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable arranged broadcasting, permitting versatile plans according to numerous needs.


Emergency Broadcasting:


It supports emergency broadcasting for the whole location, enabling one-click emergency situation interaction.


Option For Manufacturing facility



Area Broadcasting:


It permits relaying to any area, guaranteeing no interference in between different areas.


Alarm Triggering:


Terminals have numerous type of user interfaces, enabling to activate alarms when gotten in touch with video cameras.


All Network Gadgets:


Implementation of fully network tools significantly decreases the problem of running such as inspecting gadgets on dangerous websites, and hence securing people and building.


The release of all network devices considerably lowers the difficulty of operation and maintenance monitoring


Integrated SIP Phones:


The system can be integrated with SIP phone and program notifications using SIP phones any time and anywhere. Two-way sound talkback between SIP phones and IP POE Speakers makes it very easy for inspecting gadgets being in office or various other workplaces.


The XC-9000 system is a totally digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP procedure, the system ensures the appropriate and effective transmission of all information packages. The system supports various forms of audio sources for sending out alerts like real-time speech and BGM playback. In enhancement, the system offers diverse functions of sustaining different broadcasting functions such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


The system can be incorporated with the fire alarm system for control.